  |  DCS800

6.4T PROGRAMMABLE DATA CENTER SWITCH

DCS800

Wedge 100BF-32X
32 x 100G QSFP28 switch ports with Tofino 32D.
Programmable Tofino switches for data centers

DCS800 Warranty Support Period: 1 year.

The product has completed the End of Life (EOL) process effective on October 16, 2024

Para mais detalhes, consulte o Declaração de garantia do produto.

Audi
Network Packet Broker
Audi
L4 Server Load Balancer
Audi
Broadband Network Gateway
Audi
P4 Programmable Pipeline
Audi
Real-time Telemetry
Audi
OpenBMC

Visão geral

The Edgecore DCS800 switch is a Top-of-Rack (TOR) or spine switch for high-performance data centers. In a 1RU (DCS800) form factor, the switch provides line-rate L2 and L3 switching across the 32 x QSFP28 ports, supporting up to 32 x 25/40/50/100 GbE connections. The DCS800 can be deployed as a TOR switch supporting 25/50 GbE to servers with 40/50/100 GbE uplinks, or as a spine switch supporting 40/50/100 GbE spine interconnects. This open network switch is loaded with the Open Network Install Environment (ONIE), which supports the installation of compatible Network Operating System soſtware.

Características

  • Designed with programmable Tofino switch silicon from Intel Networks.
  • Deploys as top-of-rack or spine switch supporting 25 GbE to servers, with 40, 50 or 100 GbE uplinks.
  • Deploys as spine switch supporting 40, 50, or 100 GbE ToR and spine interconnects.
  • 32 x QSFP28 switch ports, each supporting 1 x 100 GbE, 1 x 50 GBE, or 1 x 40 GbE, or via breakout cables, 4 x 25 GbE or 4 x 10 GbE.
  • ​Layer 2 or Layer 3 switching switching capacity of 6.4 Tbps (full duplex).
  • Supports hot/cold aisle with port-to-power airflow SKU.
  • Todas as portas na frente; PSUs e ventoinhas acessíveis pela parte traseira.
  • Hot-swappable, load-sharing, redundant AC or 48V DC PSUs.
  • 4+1 redundant, hot-swappable fan modules.
  • Switch pre-loaded with diagnostics and with Open Network Install Environment (ONIE) for automated loading of compatible open source and commercial NOS offerings.

Compatível
Opção de software

  • Kaloom – Cloud Edge Fabric™
  • Noviflow – NoviWare
  • Open Compute Project – Open

  • Network Linux

  • SONiC

  • Stratum

Compatível
Transceptores

  • 40G QSFP+
  • 100G QSFP28

Compatível
Cabos

  • 40G QSFP+ DAC
  • 40G QSFP+ AOC

  • 100G QSFP28 DAC
  • 100G QSFP28 AOC

Transferências

DCS800 (Wedge100BF-32X) R11

Ficha de dados  3 MB

DCS800 (Wedge100BF-32X) Quick Start Guide R04

Guia de início rápido  991 KB